You can't run a test with more than one vUser per LoadGen Agent

Issue

You can't run a test with more than one vUser per LoadGen Agent; additional vUsers are not launched. The test seems to hang.

In the Dashboard of the LoadGen Director, you see the value Send from LoadBot in the Data routing option.

 

Solution 1

Make sure you can create a direct connection to the SQL server from the LoadGen Agent. This is the server name you have entered for your SQL server.

 

Solution 2

Change the Send from LoadBot option to Tunnel Useraction results through the Director.

You can achieve this by:
 
  1. In the Director, go to the Tools tab page.
  2. Press the LoadGen Options.
  3. In the tabpage session messages, check the Tunnel Useraction results through the Director check box.
Was this article helpful?
0 out of 0 found this helpful