When starting a flow with as first step a validation the Citrix session can start without a Windows Start Menu visible.
Solution
In newly created flows (from LoadGen 5.0.0.6281 release) we will automatically add a Pause as first step. In existing flows you must follow the following steps:
- Open the LoadGen Studio Recorder
- Select the first Application Block under the Logon Application
- In the Application Block add a Pause action with a minimum of 1 second